Artigo em periódico
A fuzzy type-2 fault detection methodology to minimize false alarm rate in induction motor monitoring applications
ROCHA, ERICK MELO2020ROCHA, ERICK MELO; JUNIOR, WALTERBARRA; MARCILLO, KEVIN EDUARDO LUCAS; DA COSTA JÚNIOR, CARLOS TAVARES; DE CARVALHO JÚNIOR, JOSÉ GRACILDO; DE MEDEIROS, RENAN LANDAU PAIVA; NOGUEIRA, FABRÍCIO GONZALEZ
Resumo
Resumo
Abstract Automatic routines for Fault Detection and Diagnosis (FDD) are very important in industrial monitoring systems. However, false alarms potentially occur. High false alarm rates may lead to outages and consequent losses in the production process. To address such problem, a new FDD strategy based on type-2 fuzzy systems is proposed herein to minimize the false alarm rate. By applying system identification techniques, parametric models are estimated in order to represent the operation of the system under several levels of fault severity. The test system is a detailed dynamic nonlinear model of induction motor drive. The faults considered were partial short-circuit in stator winding coils. A performance comparison was made by implementing the monitoring system with both a type-2 fuzzy system interval and a type-1 fuzzy system. The results obtained thereby showed the improved performance and robustness of type-2 fuzzy system-based monitoring system, which outdoes the performance obtained by a type-1 fuzzy system. Furthermore, the performance of the proposed type-2 fuzzy system-based monitoring system may be further improved by using a Genetic Algorithm for tuning the parameters of the fuzzy type-2 system.
Autoria
Autores do grupo (1)
A lista completa de autores está no topo da página. Abaixo, apenas os pesquisadores do e-Controls vinculados a esta publicação.
palavras-chave
Palavras-chave
fault detection and diagnosistype-2 fuzzy logic systemsfalse alarm reductionsystem identificationparametric modelstype-1 fuzzy systemsgenetic algorithm tuning
Volume
93
Páginas
106373
Editora
Elsevier BV
Status
Published
links
Links e arquivos
Artigo em periódico